Specification
Panasonic U-38ME2E8
Header Data
Active
Yes
Performance Data
Horse Power
38HP
Nominal Cooling
107 kW
Nominal Heating
119 kW
Connection Data
Maximum number of Indoor Units
64
Efficiency Data
Min - Max Connected Capacity Code
53.5 - 139.1
EER - COP
3.42 - 4.13
SEER (Office Profile)
TBC
SCOP (Office Profile)
TBC
Operation Range
Operating Range - Cooling (Outdoor Air)
-10°C to 52°C
Operating Range - Heating (Outdoor Air)
-25°C to 18°C
Operating Range - Simultaneous Op.
NA
Physical Data
Connection Kit
CZ-P1350PH2BM
Number of Modules
2
Size of Modules
18HP & 20HP
Height
1842 mm
Width
3140 mm
Depth
1000 mm
Weight
750 kg
Airflow Characteristics
Airflow Rate
13500 l/s
Static Pressure
80 Pa
Sound Data
Sound Pressure Level
62.5 - 59.5 (Cool - Heat) dB(A)
Refrigerant & Pipework
Pipe Connection Size - Gas
3/4" / 7/8" in.
Pipe Connection Size - Liquid
1 1/2" / 1 5/8" in.
Pipe Connection Size - Discharge
NA in.
Balance Pipe
1/4" in
Refrigerant
R410A
Factory Charge
19 kg
GWP (Tonnes CO2 Equivalent)
39.672
Power Data
Power Supply
400 - 3 - 50 V - Ph - Hz
Running Current (Cooling - Heating)
48.1 / 46.3 - 44.7 / 43.1 A
Power Input (Cooling - Heating)
31.3 - 28.8 kW
Starting Current
4 A
Control Details
Suggested Fuse Size
TBC A
Power Consumption Monitour
{{}}
Created with Sketch.

Panasonic U-38ME2E8

U-38ME2E8_1,Specification_Sheet.pdf
Created with Sketch.

Panasonic U-38ME2E8

U-38ME2E8_3,Dimensional_Drawing.pdf
Created with Sketch.

Panasonic U-38ME2E8

U-38ME2E8_9,Technical-Service_Manual.pdf
Created with Sketch.

Panasonic U-38ME2E8

U-38ME2E8_15,Technical-Specification.pdf